One hospital division. One nurse room with communication station 2000 S, fourteen patient rooms with communication units 2000 NU. Sockets 2000 Pab/Pa with patient buttons 2000 Paa beside beds, call buttons 2000 Pw in toilettes, call pull buttons 2000 Pd in the baths and corridor door lamps 2000 CL above the doors. Two entrances with door call stations 2000 TS1M. Communication units 2000 NU and door call stations 2000 TS1M are connected to local communication controller 2000 LCC16. System is powered by power supply 2000 ZS.
|
Needed material: | 1 | pc | Communication station 2000 S |
|
  | 1 | pc | Socket 2000 BSU | (or | 2000 BSA) |
|
  | 1 | pc | |
  | 1 | pc | Socket 2000 BSA/Z for power supply |
|
  | 1 | pc | Local communication controller 2000 LCC16 |
|
  | 14 | pcs | Communication unit 2000 NU |
|
  | 14 | pcs | Corridor door lamp 2000 CL |
|
  | 28 | pcs | |
  | 14 | pcs | |
  | 28 | pcs | Patient call button socket 2000 Pab/Pa |
|
  | 28 | pcs | Patient call button 2000 Paa |
|
  | 2 | pcs | Door call station 2000 TS1M |
|